Newcastle University
Browse
1/1
2 files

Ejector modelling for ejection refrigeration system

dataset
posted on 2016-01-01, 00:00 authored by Z Ma, H Bao, T Roskilly
The data gives all the used modelling equations and the results of an ejector for ejection refrigeration. The key finds of this modelling was the values of hypothetical throat area for the secondary fluid in the ejector, based on which empirical equations have been built for the working fluids of R134a, R141b and steam.

History

Usage metrics

    Newcastle University

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC